X
MENU

Product Archive

Products
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

15PL100

LF Drivers 15.0 inches

back
21_20_20_308_file21_20_20_358_file
Continuous power handling
Voice coil diameter
 
 
 

Features

  • 1400 W continuous program power capacity
  • 100 mm (4 in) copper voice coil
  • 35 - 2000 Hz response
  • 97 dB sensitivity
  • Double silicone spider with optimized compliance

Specifications

  • Nominal Diameter380 mm (15.0 in)
  • Nominal Impedance8 Ω
  • Minimum Impedance6.8 Ω
  • Nominal Power Handling1700 W
  • Continuous power handling21400 W
  • Sensitivity (1W/1m)397.0 dB
  • Frequency Range35 - 2000 Hz
  • Voice Coil Diameter100 mm (4.0 in)
  • Winding MaterialCopper
  • Former MaterialGlass Fibre
  • Winding Depth21.0 mm (0.83 in)
  • Magnetic Gap Depth11.0 mm (0.4 in)
  • Flux Density1.15 T

Design

  • Surround ShapeTriple Roll
  • Cone ShapeExponential
  • SpiderDouble Silicone
  • Pole DesignT-Pole
  • Woofer Cone TreatmentNone
  • Recommended Enclosure80.0 dm3 (2.83 ft3)
  • Recommended Tuning50 Hz

Parameters4

  • Resonance Frequency37 Hz
  • Re5.0 Ω
  • Qes0.21
  • Qms6.6
  • Qts0.2
  • Vas154.0 dm3 (5.4 ft3)
  • Sd855.0 cm2 (132.5 in2)
  • η₀3.6 %
  • Xmax± 7.0 mm
  • Xvar± 7.0 mm
  • Mms121.0 g
  • Bl26.8 Txm
  • Le1.7 mH
  • EBP176 Hz

Mounting and Shipping Info

  • Overall Diameter393 mm (15.5 in)
  • Bolt Circle Diameter374 mm (14.7 in)
  • Baffle Cutout Diameter354.0 mm (13.9 in)
  • Depth173 mm (6.8 in)
  • Flange and Gasket Thickness16 mm (0.62 in)
  • Air Volume Occupied by Driver0.0 dm3 (0.0 ft3)
  • Net Weight11.8 kg (26.01 lb)
  • Shipping Units1
  • Shipping Weight13.1 kg (28.88 lb)
  • Shipping Box425x425x224 mm (16.73x16.73x8.82 in)

Service Kit

  • 2 hours test made with continuous pink noise signal within the range Fs-10Fs. Power calculated on rated minumum impedance. Loudspeaker in free air.
  • Power on Continuous Program is defined as 3 dB greater than the Nominal rating.
  • Applied RMS Voltage is set to 2.83 V for 8 ohms Nominal Impedance.
  • Thiele-Small parameters are measured after a high level 20 Hz sine wave preconditioning test.