Features
- 300 W continuous program power capacity
- 70° nominal coverage
- 85 - 18000 Hz response
- 93 dB sensitivity
- 20.1 mm (0.79”) HF unit exit diameter
Specifications
- Nominal Diameter170 mm (6.5 in)
- Nominal Impedance8 Ω
- Minimum Impedance LF6.5 Ω
- Minimum Impedance HF7.0 Ω
- Frequency Range85 - 18000 Hz
- Dispersion Angle170 °
- Woofer Cone TreatmentWP Waterproof Front Side
- Magnet MaterialFerrite (LF) - Neodym. Ring (HF)
Specifications LF unit
- LF Sensitivity293.0 dB
- LF Nominal Power Handling3150 W
- LF Continuous Power Handling4300 W
- LF Voice Coil Diameter51 mm (2.0 in)
- LF Winding MaterialCopper
- LF Flux Density1.05 T
- Former MaterialKapton
- Winding Depth13.0 mm (0.51 in)
- Magnetic Gap Depth6.0 mm (0.24 in)
Specifications HF unit
- HF Sensitivity5108.5 dB
- HF Nominal Power Handling610 W
- HF Continuous Power Handling720 W
- HF Voice Coil Diameter25 mm (1.0 in)
- HF Winding MaterialAluminium
- HF Flux Density1.65 T
- Diaphragm MaterialPolyester
- Recommended Crossover82.5 kHz
- Inductance0.1 mH
Parameters
- Resonance Frequency85 Hz
- Re5.5 Ω
- Qes0.4
- Qms7.8
- Qts0.37
- Vas5.0 dm3 (0.18 ft3)
- Sd132.0 cm2 (20.5 in2)
- η₀0.83 %
- Xmax± 5.0 mm
- Xvar± 5.7 mm
- Mms16.0 g
- Bl11.3 Txm
- Le1.0 mH
- EBP212 Hz
Mounting and Shipping Info
- Overall Diameter187 mm (7.4 in)
- Bolt Circle Diameter172 mm (6.7 in)
- Baffle Cutout Diameter146 mm (5.75 in)
- Depth122 mm (4.8 in)
- Flange and Gasket Thickness12 mm (0.47 in)
- Net Weight2.7 kg (5.9 lb)
- Shipping Units1
- Shipping Weight3.15 kg (6.94 lb)
- Shipping Box255x255x150 mm (10.04x10.04x5.91 in)
- Included by –6 dB down points.
- Applied RMS Voltage is set to 2.83V.
- 2 hours test made with continuous pink noise signal within the range Fs-10Fs. Power calculated on rated minimum impedance. Loudspeaker in free air.
- Power on Continuous Program is defined as 3 dB greater than the Nominal rating.
- Applied RMS Voltage is set to 2.83V.
- 2 hour test made with continuous pink noise signal within the range from the recommended crossover frequency to 20 kHz. Power calculated on rated minimum impedance. Loudspeaker in free air.
- Power on Continuous Program is defined as 3 dB greater than the Nominal rating.
- 12 dB/oct. or higher slope high-pass filter.