Features
- 400 W continuous program power capacity
- 100° nominal coverage
- 75 - 20000 Hz response
- 94 dB sensitivity
- 34.5 mm (1.35”) HF unit exit diameter
Specifications
- Nominal Diameter210 mm (8.0 in)
- Nominal Impedance8 Ω
- Minimum Impedance LF6.3 Ω
- Minimum Impedance HF7.7 Ω
- Frequency Range75 - 20000 Hz
- Dispersion Angle1100 °
- Woofer Cone TreatmentWP Waterproof Front Side
- Magnet MaterialFerrite (LF) - Neodym. Ring (HF)
Specifications LF unit
- LF Sensitivity294.0 dB
- LF Nominal Power Handling3200 W
- LF Continuous Power Handling4400 W
- LF Voice Coil Diameter52 mm (2.0 in)
- LF Winding MaterialCopper
- LF Flux Density1.05 T
- Former MaterialKapton
- Winding Depth16.5 mm (0.65 in)
- Magnetic Gap Depth8.0 mm (0.31 in)
Specifications HF unit
- HF Sensitivity5103.0 dB
- HF Nominal Power Handling650 W
- HF Continuous Power Handling7100 W
- HF Voice Coil Diameter44 mm (1.7 in)
- HF Winding MaterialAluminium
- HF Flux Density1.8 T
- Diaphragm MaterialTitanium
- Recommended Crossover82.0 kHz
- Inductance0.11 mH
Parameters
- Resonance Frequency76 Hz
- Re5.1 Ω
- Qes0.36
- Qms5.0
- Qts0.34
- Vas11.5 dm3 (0.4 ft3)
- Sd220.0 cm2 (34.1 in2)
- η₀1.4 %
- Xmax± 6.0 mm
- Xvar± 6.0 mm
- Mms25.0 g
- Bl13.0 Txm
- Le1.0 mH
- EBP211 Hz
Mounting and Shipping Info
- Overall Diameter225 mm (8.8 in)
- Bolt Circle Diameter210 mm (8.3 in)
- Baffle Cutout Diameter187 mm (7.4 in)
- Depth129 mm (5.1 in)
- Flange and Gasket Thickness11 mm (0.4 in)
- Net Weight4.0 kg (8.82 lb)
- Shipping Weight4.6 kg (10.14 lb)
- Shipping Box295x314x175 mm (11.61x12.36x6.89 in)
- Included by –6 dB down points.
- Applied RMS Voltage is set to 2.83V.
- 2 hours test made with continuous pink noise signal within the range Fs-10Fs. Power calculated on rated minimum impedance. Loudspeaker in free air.
- Power on Continuous Program is defined as 3 dB greater than the Nominal rating.
- Applied RMS Voltage is set to 2.83V.
- 2 hour test made with continuous pink noise signal within the range from the recommended crossover frequency to 20 kHz. Power calculated on rated minimum impedance. Loudspeaker in free air.
- Power on Continuous Program is defined as 3 dB greater than the Nominal rating.
- 12 dB/oct. or higher slope high-pass filter.